Model NO.: P Series
Measuring Media: Liquid
Measuring Principle: Coriolis Force
Measurement Object: Closed Pipeline
Certification: ANS, GB, CE
Flow Meter Size: Dn10 to Dn250
Medium Available: Liquid, Gas
Accuracy Class: 0.1%F.S Under 15:1 (Measure Ratio)
Repeatability: 0.05% Under 15:1, Within Measure Ratio
Process Temperature: -40 to 350 Deg. C
Process Pressure: 0 - 1.6 MPa
Explosion-Proof: Ex Ib Iic T6
Protection Class: IP67 (Split Type)
Wetted Part: SS316L, as Required
Output: 4-20mA, 0-10kHz, Hart / Modbus
Trademark: Tosilon
Transport Package: International Export Wooden Packing, Water Proof
Specification: Based on Actual Order
Origin: Shaanxi
Tosilon Offshore Oilfield Coriolis Mass Liquid Flowmeter for Crude Oil Metering (Ex Approved)Design and Manufacturing according to CE, ATEX Standard
Introduction
P Series Coriolis Mass Flow Meter is defined as P Series Mass Flow Meter with Flow Accuracy Rate of 0.1,
consisting of "P Series Mass Flow Sensor" and "DPT Transmitter"
Features
-Â Â Â Double U or Double C Measuring Tube Design
-Â Â Â Gas Measurement Available
-Â Â Â Easy Installation, no need rectifier, filter parts, no special requirements for installing direct pipe section.
-Â Â Â High Stability, no need deploying frequent disassemble calibration
-Â Â Â Allow Low-Range Run, reducing pressure loss and energy consumption & waste
-Â Â Â Integrated Installation saving installation cost
-Â Â Â High Stability, expert in "Custody Transfer / Fiscal Metering of Oil & Gas"
General Technical Parameters (For More Details, please contact Tosilon)
Max. Mass Flow Rate | Sensor Type | Mass Flow (kg/h) | Volumetric Flow[1] (l/h) | |
P10 | 1500 | 1500 | ||
P15 | 4500 | 4500 | ||
P20 | 9450 | 9450 | ||
P25 | 25500 | 25500 | ||
P50 | 94500 | 94500 | ||
P80 | 240000 | 240000 | ||
P100 | 540000 | 540000 | ||
P150 | 825000 | 825000 | ||
P200 | 1650000 | 1650000 | ||
P250 | 2700000 | 2700000 | ||
Mass Flow Accuracy[2] | 15:1, Within Measure Ratio[3] | ±0.1% | ||
15:1, Beyond Measure Ratio | ± (Zero Stability / Instant Flow Rate) x 100% | |||
Volume Flow Accuracy[2] | Whole Measure Range ±0.15± (Zero Stability / Instant Flow Rate) x 100% | |||
Repeatability | 15:1, Within Measure Ratio | ±0.05% | ||
15:1, Beyond Measure Ratio | ±1/2 (Zero Stability / Instant Flow Rate) x 100% | |||
 | ||||
Zero Stability | Sensor Type | kg/h | ||
P10 | 0.10 | |||
P15 | 0.30 | |||
P20 | 0.63 | |||
P25 | 1.70 | |||
P50 | 6.30 | |||
P80 | 16.0 | |||
P100 | 36.0 | |||
P150 | 55.0 | |||
P200 | 110.0 | |||
P250 | 180.0 |